Skip to content

ICT Accessory/Battery Enclosure

EN-DIN-ACC

EN-DIN-ACC

The ICT Accessory/Battery Enclosure is designed to house accessories for your Protege system, including the larger batteries recommended for Protege 5A and 10A power supplies.

  • Space for two 22Ah batteries
  • Dedicated tamper switch
  • Removable door for fast installation
  • Cam lock for secure access
  • 7 conduit cable knockouts plus IEC mains knockout
  • 9 cable tie points for clean field wiring
  • IP50 rated
  • ASIAL Class 5 compatible

Features

Outage Protection

Provides space for two 22Ah batteries, enabling the system to continue operating at full load even during an extended power outage.

Easy to Install

The enclosure’s removable door, finger trunking spaces, cable tie points and convenient knockouts help you achieve a fast and clean installation.

Tamper Monitoring

Includes a dedicated tamper switch, sending a signal to the Protege system when the door is opened.

Certified

Compliant for ASIAL Class 5 installations when protected by a DSC SS-102 Shockgard seismic vibration sensor.

Specifications

Ordering Information
EN-DIN-ACCICT DIN Accessory/Battery Enclosure
Cable Entry
Cable Knockouts7 conduit cable knockouts, 1 knockout for IEC mains voltage connector
Cable Tie Points9 points for field wiring
CablesSupports the Fused Panel Mount IEC C14 Socket and the Quick Connect RS-485 Daisy Chain Cable
Earthing
Wire LoomsBond wire looms included for earth connection to the enclosure
Accessories
TamperDedicated hardware tamper input
LockCam lock
Environmental IP Rating
IP RatingIP50
Dimensions
Finger Trunking Space25mm
Dimensions (H x W x D)200 x 433 x 100.3mm (7.9 x 17 x 3.9")
Net Weight3.7kg (8.0lb)
Gross Weight4.0kg (8.8lb)
Compliance
StandardsAustralia/NZ: AS/NZS 2201:2007 Class 5

Downloads

Supporting Material
Certifications & Warranties

Regulatory Notices

AS/NZS 2201.1 Class 5

Protege systems conform to AS/NZS 2201.1:2007 Class 5 intruder alarm systems standards for the construction, operation, performance and installation of intruder alarm equipment and systems installed in clients' premises.