Tough, durable, and extremely robust, the Protege Vandal Resistant VoIP Intercom is designed to meet the harshest of environments. VoIP capability allows the Intercom to communicate with any VoIP enabled device, including smartphones, providing the ability to grant entry from virtually anywhere.

  • Vandal resistant design
  • Programmable auto-answer
  • Allows control of devices such as lights and doors
  • Noise reducing functionality to eliminate unwanted noise
  • Optional offline operation

Features

Vandal Resistant Construction

Vandal resistant body protects against malicious damage. The robust construction provides full protection against the elements, making the Intercom suitable for virtually any environment.

VoIP Capabilities

Fully VoIP compliant, the Intercom can run as a standalone point-to-point intercom or register as a phone on any VoIP capable PBX to allow normal call operation. Use with an optional VoIP server or PBX to enable complex call routing, allowing communication to multiple stations at once, routing unanswered calls to alternative stations, or diverting calls to different units based on a time schedule.

Programmable Auto-Answer

Programmable auto-answer feature provides the ability to receive broadcast announcements or gives the remote caller monitoring capability allowing them to listen in.

Eliminate Unwanted Noise

Background noise and interference is reduced leaving clear speech, while voice pick-up can be achieved from 5 meters (16ft) away.

Standalone Operation

The intercom supports standalone operation, allowing you to manage customizable schedules and configure the intercom’s onboard output for directly controlling a gate or door lock.

Power over Ethernet (PoE)

PoE simplifies installation and reduces costs. Because PoE runs data and power together over the same cable, it eliminates the time and overhead associated with AC outlet installations, while providing flexibility of the install location.

Installation Wiring

Power is provided via a suitable 12VDC supply. Ethernet connection allows for installations that use either a dedicated Protege network (recommended for multiple intercom installations) or that simply connect the Intercom and Protege Integrated System Controller to the buildings existing network.

Protege Integration

Integration allows communication to any Protege GX workstation, and provides control of devices such as lights and doors.

Specifications

Ordering Code
PRT-IPIC-POEProtege Vandal Resistant VoIP Intercom with PoE
Power Supply
Operating Voltage12VDC (9 -16VDC)
Operating Current1A
Power over EthernetIEEE 802.3af Class 3
Communication
Communication protocolSIP 2.0(RFC-3261)
Speech flow - ProtocolsRTP/SRTP
Speech flow - DecodingG.729 G.723 G.711 G.722 G.726 Codecs
Speech flow - Audio Amplifier2.5W
Speech flow - Volume ControlAdjustable
Speech flow - Full duplex speakerphoneSupport (AEC)
Port - Recording outputOne (3.5mm terminal block)
Port - Short circuit inputTwo (3.5mm terminal block)
Port - Short circuit outputTwo Form C relays (3.5mm terminal block) 24V DC 1A
Port - WAN port10/100BASE-TX s Auto-MDIX, RJ-45
Port - LAN port10/100BASE-TX s Auto-MDIX, RJ-45
CablesCAT5 or better
Audio
MicrophoneOmnidirectional
SpeakerTY 4 ohm 3W
Environment
Environmental IP RatingIP65
Working temperature-40° to 70° Celsius (-40° to 158° Fahrenheit)
Working humidity10% to 95%
Storage temperature-40° to 70° Celsius (-40° to 158° Fahrenheit)
Dimensions
Overall dimensions195 x 120 x 39mm (7.67 x 4.72 x 1.53")
Net Weight960g (33.86oz)
Gross Weight1200g (42.3oz)

Regulatory Notices

RCM (Australian Communications and Media Authority)

This equipment carries the RCM label and complies with EMC and radio communications regulations of the Australian Communications and Media Authority (ACMA) governing the Australian and New Zealand (AS/NZS) communities.

CE - Compliance with European Union (EU)

Conforms where applicable to European Union (EU) Low Voltage Directive (LVD) 2014/35/EU, Electromagnetic Compatibility (EMC) Directive 2014/30/EU, Radio Equipment Directive (RED) 2014/53/EU and RoHS Recast (RoHS2) Directive: 2011/65/EU + Amendment Directive (EU) 2015/863.

This equipment complies with the rules, of the Official Journal of the European Union, for governing the Self Declaration of the CE Marking for the European Union as specified in the above directives.

UK Conformity Assessment (UKCA) Mark

This equipment carries the UKCA label and complies with all applicable standards.

Industry Canada

ICES-003

This is a Class A digital device that meets all requirements of the Canadian Interference-Causing Equipment Regulations.

CAN ICES-3 (A)/NMB-3(A)

Federal Communications Commission (FCC)

FCC Rules and Regulations CFR 47, Part 15, Class A.

This equipment complies with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference; (2) This device must accept any interference received, including interference that may cause undesired operation.